Latest Allbrite news

 

Ribbon Mats - Vinyl (Light Foot Traffic)

Carpet


Floor Preparation

When installing under floor heating with vinyl floor there is very little floor preparation needed, it is important that the subfloor is flat and smooth (Latex level compound may be needed). When the floor is flat ensure that it is free from dust and debris.

Installation Steps

  1. Roll out your 6mm therm-all insulation and cut so it covers the whole floor
  2. Lay your ribbon under floor heating mats on the insulation
  3. Use double sided tape on mats to stick the under floor heating mats to the insulation
  4. Where required use additional high adhesive tape to ensure the heating mats are secured
  5. Route the cold leads (live & neutral) to a junction box just above skirting board level
  6. Check the resistance of the heating elements matches with the resistance chart in installation manual
  7. Connect the cold leads using the revolutionary 5 lever quick connectors
  8. Lay the heat-pak overlay board over the top of the underfloor heating, then lay your vinyl floor over the top of the heat-pack
  9. See Electrical section for setting up electrics, if installing in a wet area please see grounding kits
  10. Sit back and enjoy